TM 5-3610-259-14
2-20.6 Replace Strike Transformer (ST-1 or 2).
MOS: 35E, Special Electronic Devices Repairer
TOOLS:
Tool Kit, Electronic Repair
Flat Tip Screwdriver
Hex Head Key Wrench Set
Slip Joint Pliers
SUPPLIES: 3kW Strike Transformer
WARNING
Death or serious injury may occur from electrical shock unless power is turned
off before servicing.
a.
Perform steps a-k of paragraph 2-20.5 to remove 3kW power supply circuit
board.
b. Tag and disconnect wires for defective strike transformer.
c.
Loosen mounting screws for both high voltage and coil insulator
brackets, and remove defective strike transformer.
d. Install new strike transformer onto high voltage and coil insulator
brackets and tighten mounting screws.
e.
Reconnect wires for new strike transformer that was removed in step b.
f. Perform steps n-x of paragraph 2-20.5 to install 3kW power supply
circuit board.
2-112