TM 5-3610-259-14
g.
h.
i.
j.
k.
1.
m.
n.
o.
P.
q.
r.
s.
t.
u.
v.
w.
x.
Maneuver power supply carefully out of platemaker, and position on
floor.
Tag and disconnect wires from power supply terminal strip.
Tag and disconnect plug connectors for strike transformers.
Tag and disconnect wires for strike transformer #2 proximity switch.
Remove mounting screws and wire retaining clips for circuit board. and
remove defective 3kW power supply circuit board.
Remove strike transformer #2 proximity
supply circuit board.
Install strike transformer #2 proximity
circuit board.
Install new 3kW power supply circuit
retaining clips onto supports.
switch from defective power
switch on new power supply
board, mounting screws, and wire
Reconnect wires for strike transformer #2 proximity switch.
Reconnect plug connectors for strike transformers.
Reconnect wires to power supply terminal strip.
Carefully reposition power supply in platemaker.
Reconnect wires on terminals 1 through 5 on autoformer terminal strip.
Reconnect top overtemperature switch leads to each strike transformer.
Secure power supply to platemaker chassis with two hex head screws, flat
washers, and star washers.
Reinstall right side lowered panel.
Reinstall lower cabinet panel.
Turn on power panel circuit breaker.
2-111