TM 5-3610-259-14
g.
Fluorescent Ceiling Lights.
Two-level (high/low) overhead lights with
blackout override switches.
h.
Emergency Lights. Battery-powered. Activated by power loss.
i.
Air Conditioner/Heater. Air conditioner and electrical heater powered by
three-phrase, 208 v, 30 amp current.
j.
Blackout Lights.
Red-lensed, 12 vac lights actuated when blackout switch
operates.
k. Power Cables. (120/208 vac and 12 vdc.) Power input.
1.1.3.3 WIRING DIAGRAM.
A foldout wiring diagram is provided at the end of this
manual.
1.1.3.4 VENTILATION SYSTEM
RECIRCULATING
Al R
REPLACEMENT
Al R
EXHAUST
Al R
Exhaust fans exhaust air.
Replacement air flows into the van body through the air
vent filter.
Recirculating air is filtered as it enters the air conditioners/
heaters.
From the air conditioners/heaters, it flows through the ceiling vents and
into the van body.
Detailed description of air conditioner/heater operation is contained in TM 5-4120-
367-14, Operators Organizational, Direct Support, and General Support Maintenance
Manual, Air Conditioner, Horizontal, Compact, 18,000 BTU/hr Cooling, and TM 5-4120-
367-24P, Organizational, Direct Support, and General Support Maintenance Repair
Parts and Special Tools List (Including Depot Maintenance Repair) for Air Condi-
tioner, Horizontal, Compact, 18,000 BTU/hr cooling.
1-10