TM 5-3610-259-14
3.
Disconnect vent line from tank.
4. Disconnect drain line from tank.
5. Drill rivets from covers on outside of section.
6. Remove covers.
WARNING
WEIGHT AND LOCATION OF WATER TANK REQUIRES
TWO PERSONNEL TO REMOVE TANK TO AVOID PER-
SONAL INJURY OR DAMAGE TO EQUIPMENT.
7.
Remove bolts, locknuts, and washers and replace tank.
8. Align tank with holes, replace bolts, washers and secure with
locknuts.
NOTE
Use pipe compound on assembly of piping
to be sure that there are no leaks.
9. Reconnect supply line, vent line and drain line to tank.
10. Fill tank.
Check for leaks.
11. Coat inside of covers with RTV compound. Reinstall covers over
bolts on outside of section.
12. Rivet covers.
13. Paint outside covers as required.
1-92