TM 5-3610-257-14
Table 8-2. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
RED ILLUMINATION UNEVEN.
Step 1.
Check for loose or burned out incandescent light(s).
Tighten or replace defective incandescent light(s).
Step 2.
Check for flickering or dimly lit incandescent light(s).
Replace defective incandescent light(s).
4.
NO WHITE ILLUMINATION (RED ILLUMINATION NORMAL).
Refer to organizational maintenance.
5.
NO RED ILLUMINATION (WHITE ILLUMINATION NORMAL).
Refer to organizational maintenance.
8-10.
MAINTENANCE PROCEDURES. There are no operator maintenance procedures assigned for this equipment.
Section IV. ORGANIZATIONAL MAINTENANCE
8-11.
LUBRICATION INSTRUCTIONS. This equipment does not require lubrication.
8-12.
REPAIR PARTS, SPECIAL TOOLS; TEST, MEASUREMENT, AND DIAGNOSTIC EQUIPMENT (TMDE); AND
SUPPORT EQUIPMENT.
8-12.1. Common Tools and Equipment. For authorized common tools and equipment, refer to the Modified Table of
Organization and Equipment (MTOE) applicable to your unit.
8-12.2. Special Tools; Test, Measurement, and Diagnostic Equipment; and Support Equipment. Special Tools,
TMDE, and Support Equipment is listed in the applicable repair parts and special tools list and in Appendix B of this
manual.
8-12.3. Repair Parts. Repair parts are listed and illustrated in the Repair Parts and Special Tools List, TM 5-3610-257-
24P covering organizational maintenance for this equipment.
8-9