TM 5-3610-257-14
Table 7-2. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
CAUTION
Glass surface must be handled with care to avoid chipping or breaking.
Step 2. Remove glass surface. Remove plexiglass.
Step 3. Plug in power cord, turn on power, and observe fluorescent tubes.
(a)
If one fluorescent tube flickers or is dark, replace tube (paragraph 7-10.1).
(b)
If reflector is dirty behind fluorescent tube, clean reflector.
(c)
If both fluorescent tubes flicker, replace ceramic condenser (paragraph 7-10.2).
7-10.
MAINTENANCE PROCEDURES.
a.
This section contains instructions covering operator maintenance functions for the light table cabinet. Personnel
required are listed only if the task requires more than one.
b.
After completing each maintenance procedure, perform operational check to be sure that equipment is properly
functioning.
INDEX
PROCEDURE
PARAGRAPH
Replace Fluorescent Tube ............................................................................................... 7-10.1
Replace Ceramic Condenser ........................................................................................... 7-10.2
Replace Glass .................................................................................................................. 7-10.3
7-9