TM 5-3610-257-14
5-2.2.
Location and Description of Major Components.
COMPRESSOR. Compresses freon gas to perform refrigeration process.
CONDENSER COILS. Air-cooled condenser coils remove heat from compressed freon gas.
HEAT EXCHANGER. Contains refrigeration evaporator coils for cooling and electrical resistance heater for warming
water.
RECYCLING PUMP. Magnetic-drive, centrifugal pump used to circulate water through heat exchanger and into sink.
CABINET EVAPORATOR. Cools cabinet through expansion of freon gas from compressor. It has a fan to aid airflow
through coils.
CABINET THERMOSTAT. Controls refrigeration cabinet temperature. Adjustable.
SINK THERMOSTAT. Controls temperature of water in sink. Adjustable.
5-2