TM 5-3610-257-14
EXPOSURE RECORD
Screen
Separation
Filter
Screen Range
EXPOSURE
FLASH
MAIN
HIGHLIGHT
OTHER
LENS STOP
TIME UNITS
CONTROL
AND
DIRECTION
(8)
Check predetermined .50 step. If negative has a 50% dot, exposure is proper. Record this setting on
exposure record card. This setting is now the normal MAIN UNIT setting.
(9)
If 50% dot is on another step, read density of this step and find the difference between this and desired 50%
step.
(10)
If difference found in above step indicates density is less, proper exposure will be less; if greater, exposure
must be more.
3-33