TM 5-3610-257-14
Table 1-6. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
LIGHT LEAKS AROUND DARKROOM DOOR ASSEMBLY.
Check for defective magnetic door gasket.
Replace door gasket (paragraph 1-20.9).
7.
LIGHT LEAKS AROUND BOTTOM OF DARKROOM DOOR ASSEMBLY.
Check for defective threshold seal.
Replace seal (paragraph 1-20.10).
8.
LIGHT LEAKS AROUND PANEL OF DARKROOM PARTITION ASSEMBLY.
Check for openings between top frame, ceiling fan and partition panel.
Seal openings with silicone sealant.
9.
DARKROOM IN USE INDICATOR LIGHT DOES NOT TURN ON.
Step 1.
Check for defective darkroom in use indicator light assembly.
a. If assembly is operative, proceed to step 2.
b. Replace defective assembly (paragraph 1-20.11).
Step 2.
Check for defective darkroom in use light switch.
Replace switch (paragraph 1-16.4).
1-98