TM 5-3610-253-14
6-2.2
Location and Description of Major Components.
BLOWER HOUSING.
Covers and contains blower, blower brushes, control switch, air
intake, and air intake flow control.
STAND.
Plastic stand is mounted to right blower housing. Stand adjusts to allow
nozzle to be pointed in any position from vertical to horizontal.
HEATING ELEMENTS. Radiates heat to warm airflow.
BLOWER.
Is driven by electric motor and draws air into adjustable air intake and
forces it through heating element and out nozzle.
6-2.3
Equipment Data.
Air Volume
27 CFM
Air Velocity
975 FPM
Nozzle Air Opening
1.19 in. (3.02 cm)
Air Temperature Range
Weight
2.75 lbs (1.25 Kg)
Voltage
115 V, 50-60 Hz
Current Consumption
19 amps
6-3. TECHNICAL PRINCIPLES OF OPERATION. Technical principles of operation are
combined with the description and use of operators controls and indicators.
6-2