TM 5-3610-287-10
Table 3-1.
Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10.
AIR CONDITIONER/HEATERS DO NOT OPERATE.
Refer to TM 5-4120-367-14.
11.
WALL HEATERS DO NOT OPERATE.
Check that circuit breaker is in ON position.
Turn circuit breaker to ON.
If malfunction still exists, notify your supervisor.
12.
BLACKOUT LIGHTS DO NOT OPERATE.
Check that blackout switches are set correctly.
Step 1.
Reset blackout switches by turning BLACKOUT BYPASS
switch to OFF and BLACKOUT LIGHT switch to ON.
Step 2.
Check to see that striker plate(s) contacts roller on
microswitch.
Loosen screws and move striker plate(s) up or down until
microswitch operates.
Check for burnt out bulb(s).
Step 3.
If malfunction still exists, notify your supervisor.
13.
EXHAUST FAN DOES NOT OPERATE.
Step 1.
Check that exhaust fan switch is ON.
Turn switch ON.
Step 2. Check that exhaust fan plug is connected to FAN RECEPTACLE
wall outlet.
Connect plug.