TM 5-3610-252-14
c.
Place wiping cloth around reservoir to minimize spillage of hydraulic
fluid when reservoir is removed.
d. Grasp reservoir firmly and pull from housing.
e.
Dispose of hydraulic fluid in reservoir as required. Remove plug from
reservoir and set aside for future use.
NOTE
Be sure new reservoir is properly positioned to prevent fluid leaks.
f. Place new reservoir in position and slide onto projection in housing,
g.
Wipe plug clean and install on new reservoir.
h. Fill with hydraulic fluid and bleed air from system.
2-23