TM 5-6675-328-14
e. Remove cover plate; tag and disconnect terminal board wiring.
f. Remove cable clamps above drawer.
g. Tag and remove wires from terminal board located next to transformer assembly.
h. Remove power control panel with attached five-wire cables.
i. Remove target post mounting capscrews, washers, and self-locking nuts.
j. Remove target post.
k. Remove mounting bolts and lockwashers from each shock mount.
l. Raise calibrator using leveling screws.
WARNING
Severe personnel injury may occur if calibrator is moved in the section without using
adequate lifting equipment. Use care and use only approved lifting equipment.
m. Position pallet jack under calibrator and raise off of base plate. Remove leveling screws.
n. Move calibrator to rear door and remove from section using forklift.
NOTE
Reinstall target post on calibrator after removal of calibrator from section. Remove target
post from replacement calibrator before installing in section.
o. Install calibrator in section using forklift and pallet jack.
p. Position replacement calibrator over base plate and line up shock mounts.
q. Reinstall leveling screws, remove pallet jack, and lower calibrator on shock mounts.
r. Reinstall bolts and lockwashers to secure calibrator to shock mounts.
2-74