TM5-6675-326-14
Table 1-1.
Operator Preventive Maintenance Checks and Services - Continued
B - Before Operation
D - During Operation
A - A f t e r O p e r a t i o n
W - Weekly
Item
No.
3
I n t e r v al
Q - Quarterly
ITEM TO BE INSPECTED
Equipment Is
Not Ready/Available
PROCEDURE
I f :
GROUND CONNECTIONS. Check to see
if ground cable is connected to
terminal lug in power entry panel
and to ground rod.
WARNING
ELECTRICAL SHOCK
Power cable must be disconnected
before servicing power entry
panel connections.
F a i l u r e to
do so may result in death or
s e r i o u s i n j u r y.
Check ground connections for dirt
or foreign matter.
Clean connec-
tions by removing ground cable
and brushing cable wires and
ground lug on power entry panel
with wire brush.
Ground connections
are broken or
missing.
1-15