TM 5-6675-325-14
Table 1-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
A N
- Annually
D - During
M - Monthly
s
A - After
- Semiannually
Q - Quarterly
BI - Biennially
lTEM
NO.
1
IN-
TER
VAL
B
B/D/
A
Q
ITEM TO BE INSPECTED
PROCEDURE
VAN BODY - Cent
Inspect Exterior - Cont
a.
b.
c.
d.
e.
f .
g.
h.
9*
a.
b.
c.
10.
11.
WARNING
Electrical shock hazard. Power cable must be
deenergized before servicing entry panel
connections.
Death can result from failure to
observe these safety precautions.
Turn power off to cable. Disconnect from power
source.
Disconnect ground lug from ground rod.
Clean lug, cable end, and rod with wire brush.
Reconnect ground cable lug to rod.
Disconnect ground cable end from entry panel.
Clean terminal and cable end with wire brush.
Reconnect ground cable to entry panel.
Reconnect cable to power source. Turn power on.
Inspect boarding ladders for:
Secure attachment of handrails.
Steps not broken.
Locking pins in place.
Inspect front and rear van body locks to be sure
locks are fully engaged.
Inspect gaskets on personnel doors for leaks or
damage.
(Number)
- Hundreds of Hours
For Readiness
Reporting,
Equipment is
Not Ready/
Available If:
Steps are
broken or
w i l l n ot
lock in
place.
Lock dis-
engaged.
1-18