TM 5-6675-325-14
1-2.4 Equipment Data - ISO Container (Unmounted).
Dimensions
Length
Width
Height
Cubage
Connections
Telephones
Power
33.66 ft (10.26m)
8 f t ( 2 . 4 4 m)
8 ft (2.44 m)
2154 ft3 (61.0 m3)
One telephone (three-
post) connection
13.6 kW.
One 120/208 V,
three-phase, four-wire
connection and one 12 V
dc connection
Ground
Ground lug
Air Conditioner/Heater (Two Units)
Cooling
Heating
Power Requirements
Exhaust Fan
Air Vent
Weight
Gross (Container and Chassis)
Tare (Container Only)
1-3. TECHNICAL PRINCIPALS OF OPERATION.
18.000 Btu/hr (5274 W)
E a c h
14,300 Btu/hr (4190 W)
( M a x ) E a c h
208 V, 60 Hz, three-phase
289 ft3/min (8.18 m3/ m i n)
289 ft3/min (8.18 m3/ m i n)
25,390 1bs (11,514.37 kg)
13,950 1bs (6326.33 kg)
1-3.1 General.
The operation of major components located in the section are
explained in the appropriate chapter for that equipment.
1-8