TM 5-6675-324-14
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
Table 5-1.
(Number) - Hundreds of Hours
AN - Annually
W - Weekly
B - Before
S
- Semiannually
M - Monthly
D - During
BI - Biennially
Q - Quarterly
A - After
For Readiness
ITEM TO BE INSPECTED
Reporting,
lN-
ITEM
Equipment Is
TER-
PROCEDURE
NO.
Not Ready/
VAL
Available If:
QUANTITY PROCESSING SYSTEM (PLANIMETER) - Cont
3
B
Inspect Calculator - Cent
Ribbon
3.
Inspect ribbon cable and power jacks for cracks
cable or
or breaks.
power jacks
are damaged.
4.
Wipe dirt and dust from calculator with soft
cloth .
CAUTION
Use head cleaning card only after con-
tinued use of preprogrammed card. Head
cleaning card is abrasive. Damage to
calculator reader could result. -
5. Clean magnetic card reader heads with head
cleaning card.
3
M
Wipe magnetic cards with soft cloth moistened
with alcohol.
5-32