TM 5-6675-323-14
Table 9-5. TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. AUTO-SCALER DOES NOT OPERATE.
S t e p 1.
auto-scaler back panel.
(a) If power transformer is plugged in, proceed to step 2.
(b) Plug in power transformer.
Step 2.
(a) If circuit breaker is on, refer to organizational
maintenance.
(b) Turn on circuit breaker.
CALCULATOR DOES NOT OPERATE.
2.
Step 1.
back of calculator.
(a) If power transformer is plugged in, proceed to step 2.
(b) Plug in power transformer.
S t e p 2.
(a) If circuit breaker is turned on, refer to organizational
m a i n t e n a n c e and proceed to step 3.
(b) Turn on circuit breaker.
Check to see if calculator will energize with good battery pack.
Step 3.
(a) If calculator energizes, replace power transformer.
(b) If calculator does not energize, replace calculator.
9-125