TM 5-6675-323-14
Reinstall mounting screws.
j.
k. Reinstall cover plate and secure with screws.
l.
1-16.5 Replace Blackout/Dome Light Microswitch.
MOS:
41B, Topographic Instrument Repair Specialist
TOOLS:
Flat Tip Screwdriver
6 in. Adjustable Wrench
Microswitch
SUPPLIES:
WARNING
Death or serious injury may occur from electrical shock unless power is
off before servicing.
a.
b. Remove conduit cover.
Remove nut and pull out switch to expose wiring.
c.
d.
Disconnect
wires
from
defective
switch.
Connect wires to new switch.
e.
f.
Install switch and secure with nut.
Adjust striker plate until plate contacts roller.
g.
h. Reinstall conduit cover.
i.
1-68