TM 5-6675-323-14
1-7.
OPERATION UNDER UNUSUAL CONDITIONS.
NOTE
Damage to container permitting light leaks, water, or dirt entry must be
temporarily repaired using available material on hand. Maintenance person-
n e l w i l l c o n d u c t p e r m a n e n t r e p a i r s ; h o w e v e r , c r e w must maintain operation-
al capability of section.
1-7.1 Operation in High Wind or Storm Conditions.
a.
Relocate section if trees or structures present hazard.
b. Secure section corners at lifting eyes to deadmen or substantial objects.
c.
Remove all loose objects from area.
a.
The operation of the internal equipment is performed within environmentally
c o n t r o l l e d conditions; however, in extreme cold, the main power supply cable and
ground cable will become hard, brittle, and difficult to handle. When connecting or
disconnecting cables, be careful that kinks and unnecessary loops will not result in
permanent damage.
b. Make certain that connections and cable receptacles on the outside of the
section are free of frost, snow, and ice.
c . When section heaters are not operating or when the section is being trans-
ported, liquid consumable supplies may freeze, break their containers, then melt,
Store these items in an area to prevent equipment
a n d ruin equipment or documents.
and document damage.
1-42