TM 5-6675-322-14
9-6.2 Operating Procedures.
a.
Magnifier lamp.
(1) Move magnifier lamp from mounting bracket.
(2) Plug in power cord.
(3) Turn on fluorescent lamp .
( 4 ) P o s i t i o n m a g n i f i e r l a m p o v e r o b j e c t.
(5) Examine object through lens.
b. Vacuum cleaner.
(1) Using as vacuum.
(a) Attach dust collection bag to air discharge opening.
(b) Remove protective screen lock from air intake opening and attach
scrap trap to that opening .
(c) Attach swivel end of hose to scrap trap by turning lock to right
u n t i l s e c u r e.
(d) Attach required tool to other end of hose.
(e) Insert plug into 120 V ac wall outlet and turn ON/OFF switch to ON.
( 2 ) U s i n g a s b l o w e r .
(a) Attach tapered rubber nozzle to discharge opening.
( b ) A t t a c h p r o t e c t i v e s c r e e n l o c k t o a i r i n t a k e o p e n i n g .
(c) Insert plug into 120 V ac wall outlet and turn ON/OFF switch to ON.
( 3 ) U s i n g a s s p r a y e r .
( a ) A t t a c h p r o t e c t i v e s c r e e n l o c k t o a i r i n t a k e o p e n i n g .
(b) Attach swivel end of hose to air discharge opening by turning lock
t o r i g h t u n t i l s e c u r e .
(c) Attach sprayer to other end of hose .
NOTE
Size of spray pattern is determined by adjusting screw located on top of
s p r a y e r.
9-41