TM 5-6675-322-14
d .
e .
f .
g.
h.
i .
j .
Remove socket head screws, lockwashers, and nuts that secure ballast.
Lift ballast out of table to gain access to wire connectors .
Tag and disconnect all wires.
I n s t a l l n e w b a l l a s t.
NOTE
Be sure wires are not kinked.
Reconnect all wires.
Secure ballast with nuts, lockwashers, and socket head screws.
Reinstall right panel and secure with socket head screws.
k .
Plug in power cord.
2-27