TM 5-6675-322-14
Table 2-3. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
LAMPS DO NOT LIGHT.
Step 1.
Check continuity of power switch.
( a ) I f c o n t i n u i t y e x i s t s , p r o c e e d t o s t e p 2.
( b ) I f C o n t i n u i t y e x i s t s , r e p l a ce
2-16.1).
Step 2.
Check continuity of power cord.
(a) If no continuity exists, replace
2-16.2).
p o w e r s w i t c h ( p a r a g r a p h
p o w e r c o r d ( p a r a g r a p h
( b ) I f c o n t i n u i t y e x i s t s , r e p l a c e t u b e s t a r t e r ( p a r a g r a p h 2 - 1 6 . 5 ) .
( c ) l f l a m p s s t i l l d o n o t l i g h t , r e p l a c e b a l l a s t ( p a r a g r a ph
2-16.4).
2.
POWER RECEPTACLES DO NOT WORK.
Step 1.
Check continuity of power cord.
( a ) I f c o n t i n u i t y e x i s t s , p r o c e e d t o s t e p 2 .
(b) If noc oontinuity exists, replace power cord (paragraph
2-16.2).
Step 2.
Check continuity of receptacle.
Repair receptacle (paragraph 2 - 16 . 3).
3 .
TABLE DOES NOT LOCK.
Step 1.
C h e c k f o r l o o s e t i l t l o c k.
( a ) I f t i g h t , p r o c e e d t o s t e p 2.
( b ) T i g h t e n t i l t l o c k .
2-17