TM 5-6675-321-14
Table 1-4. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. NO POWER TO EQUIPMENT - Cont
Step 3.
Check circuit breaker output for 120 V ac.
(a) If output voltage is present, proceed to step 4 .
( b ) I f o u t p u t v o l t a g e i s n o t p r e s e n t , r e f e r t o d i r e c t / g e n e r a l
support maintenance for circuit breaker replacement
(paragraph 1-20.5).
Step 4.
Remove receptacle and check for 120 V ac input.
( a ) I f p r e s e n t , r e p l a c e r e c e p t a c l e ( p a r a g r a p h 1 - 1 6 . 6 ).
( b ) I f n o t p r e s e n t , r e f e r t o d i r e c t / g e n e r a l s u p p o r t m a i n t e n a n c e
for repair or replacement of defective wiring.
1-16. MAINTENANCE PROCEDURES.
This section contains instructions covering organizational maintenance
functions for the Mosaicking/Drafting Section.
Personnel required are listed
only if the task requires more than one.
b. After completing each maintenance procedure, perform operational check to be
sure that equipment is properly functioning.
INDEX
PROCEDURE
PARAGRAPH
Replace Fluorescent Lamp Ballast . . . . . . . . . . . . . . . . . . . 1-16.1
Replace Radio Frequency (RF) Filter . . . . . . . . . . . . . . . . . . 1-16.2
Replace Fluorescent Lamp Switch . . . . . . . . . . . . . . . . . . . . 1-16.3
Replace On/Off Switch. . . . . . . . . . . . . . . . . . . . . . . . . 1-16.4
Replace Blackout/Dome Light Microswitch . . . . . . . . . . . . . . . . 1-16.5
1-57