TM 5-6675-321-14
Table 1-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S
- Semiannually
A - After
Q - Quarterly
BI
- Biennially
ITEM
NO.
2
3
4
B/W
B
M
1
ITEM TO BE INSPECTED
PROCEDURE
VAN BODY - Cont
I n s p e c t I n t e r i o r - C o nt
d.
Inspect contents for damage. Then use checklist
to inventory contents.
e.
Replace damaged or missing items.
f . R e p a c k k i t .
g.
R e i n s t a l l k i t .
12.
Inspect blackout curtains.
a.
Inspect blackout curtains and valances for
tears, missing hooks, or broken eyelets.
b .
Inspect nylon hook and pile tape on curtain
and wall for security of attachment.
Inspect Air Conditioner/Heater. Refer to TM 5-4120-
367-14 for preventive maintenance checks and services.
Service Power Cable.
WARNING
Electrical shock hazard. Power cable mus t
be de-energized before servicing. Death or
serious injury may occur from failure to
observe this safety precaution .
1.
Turn off safety switch .
2.
Disconnect cable from power entry panel .
3.
Wrap any cuts or abrasions in cable with electrical
i n s u l a t i o n t a p e.
4.
Reconnect power cable to entry panel.
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
Curtains
damaged.
1-23