TM 5-6675-321-14
Table 2-3. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
LAMPS DO NOT LIGHT.
Step 1.
Check continuity of power switch.
( a ) I f c o n t i n u i t y e x i s t s , p r o c e e d t o s t e p 2.
( b ) I f n o c o n t i n u i t y e x i s t s ,
replace power switch (paragraph
2 - 1 6 . 1 ).
Step 2.
Check continuity of power cord.
( a ) I f n o c o n t i n u i t y e x i s t s,
replace power cord (paragraph
2-16.2).
( b ) I f c o n t i n u i t y e x i s t s ,
replace tube starter (paragraph 2-16.5) .
( c ) I f l a m p s s t i l l d o n o t l i g h t , r e p l a c e b a l l a s t ( p a r a g r a ph
2-16.4).
2 .
POWER RECEPTACLES DO NOT WORK.
Step 1.
Check continuity of power cord.
( a ) I f c o n t i n u i t y e x i s t s , p r o c e e d t o s t e p 2.
( b ) I f n o c o n t i n u i t y e x i s t s,
replace power cord (paragraph
2-16.2).
Step 2.
Check continuity of receptacle .
Repair receptacle (paragraph 2-16.3).
3.
TABLE DOES NOT LOCK.
Step 1.
Check for loose tilt lock.
( a ) I f t i g h t , p r o c e e d t o s t e p 2.
( b ) T i g h t e n t i l t l o c k .
2-17