a .
Drill pop rivets from hinged cover to remove cover.
b. Remove defective cover and transfer mounting hardware to new cover.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially dan-
gerous to personnel and property.
Avoid repeated and prolonged skin
c o n t a c t.
Wear solvent-impermeable gloves and eye/face protective
equipment when using solvent.
Do not use near open flame or excessive
heat .
Flash point of solvent is 100°F to 138° F (38°C to 59° C).
c .
Scrape gasket off section and clean area with solvent P-D-680.
d. Secure new gasket to section with adhesive.
e .
Aline exhaust fan cover and pop rivet to hinge.
f . T e s t c o v e r f o r t i g h t n e s s o f c l o s u r e.
1-75