TM 5-6675-320-14
7-16.1 Replace Magnifier Lamp Assembly.
MOS: 81C, Cartographer
TOOLS :
Flat Tip Screwdriver
SUPPLIES: Magnifier Lamp Assembly
WARNING
Death or serious injury may occur from electrical shock if power cord is
not unplugged before servicing.
a.
U n p l u g p o w e r a n d r e m o v e m a g n i f i e r l a m p a s s e m b l y f r o m b r a c k e t .
b. Remove screws to release bracket from wall.
c.
Install new bracket and secure with screws.
d.
Install new magnifier lamp assembly on bracket and plug in power cord.
7-17. PREPARATION FOR STORAGE OR SHIPMENT. Contact your battalion for packing and
shipping instructions.
Section V DIRECT/GENERAL SUPPORT MAINTENANCE
There are no direct/general support maintenance procedures assigned for this
equipment.
7-15/(7-16 blank)