TM 5-6675-320-14
Table 53. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
LAMPS DO NOT LIGHT.
Step 1.
Check continuity of power switch.
( a ) I f c o n t i n u i t y e x i s t s , p r o c e e d t o s t e p 2.
(b) If no continuity exists, replace power switch (paragraph
5-16.2).
Step 2.
Check continuity of power cord.
( a ) I f n o c 0 n t i n i n u t y e x i s t s,
replace power cord (paragraph
5-16.2).
( b ) I f c o n t i n u i t y e x i s t s ,
replace tube starter (paragraph 5-16.5).
( c ) I f l a m p s s t i l l d o n o t l i g h t , r e p l a c e b a l l a s t ( p a r a g r a ph
5-16.4).
2.
POWER RECEPTACLES DO NOT WORK.
Step 1.
Check continuity of power cord.
( a ) I f c o n t i n u i t y e x i s t s , p r o c e e d t o s t e p 2.
(b) If no continuity exists, replace power cord (paragraph
5-16-.2).
Step 2.
Check continuity of receptacle.
Repair receptacle (paragraph 5 - 16 . 3) .
3 .
TABLE DOES NOT
Step 1. Check
( a)
(b)
LOCK.
f o r l o o s e t i l t l o c k .
I f t i g h t , p r o c e e d t o s t e p 2.
T i g h t e n t i l t l o c k .
5-17