Table 4-13. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6 .
PLOTTER DOES NOT DRAW EXPECTED PLOT OR PLOT APPEARS INACCURATE.
Step 1.
Check program for incorrect or misplaced syntax.
(a) If program is correct, proceed to step 2 .
(b) Correct program.
Step 2.
Perform Operators HP-IB operational test (paragraph 4-6.2d).
Refer to vendor for servicing.
7. PLOTTER WILL NOT RESPOND TO DIGITIZE COMMAND OR TRANSFER COORDINATES.
Step 1.
Check that LISTEN ONLY switch is set to 0 (talk and listen).
(a) If LISTEN ONLY switch is properly positioned, proceed to step
2.
(b) Set LISTEN ONLY switch to 0.
Step 2.
Check to see if ERROR or OUT OF LIMIT lamp on front panel is lit.
( a ) I f n e i t h e r l a m p i s l i t , p r o c e e d t o s t e p 3.
(b) Correct error in program syntax .
Step 3.
Perform Operators HP-IB operational test. (4-6.2d)
Refer equipment to vendor for servicing.
4-10. MAINTENANCE PROCEDURES.
There are no operator maintenance procedures
assigned for this equipment .