TM 5-6675-320-14
Section V DIRECT/GENERAL SUPPORT MAINTENANCE
1-18. REPAIR PARTS, SPECIAL TOOLS; TEST, MEASUREMENT, AND DIAGNOSTIC EQUIPMENT
(TMDE); AND SUPPORT EQUIPMENT.
1-18.1 Common Tools and Equipment.
For authorized common tools and equipment,
refer to the Modified Table of Organization and Equipment (MTOE) applicable to your
u n i t .
1-18.2
Special Tools; Test, Measurement, and Diagnostic Equipment; and Suport
Equipment.
Special Tools, TMDE, and Support Equipment is listed in the applicable
repair parts and special tools list and in Appendix B of this manual.
1 - 1 8 . 3 R e p a i r P a r t s .
Repair parts are listed and illustrated in the Repair Parts
and Special Tools List, TM 5-6675-320-24P covering direct/general support
maintenance for this equipment.
1 - 1 8 . 4 E l e c t r i c a l S y s t e m .
Direct/general support level of maintenance for the
r e p a i r o f t h e s e c t i o n s e l e c t r i c a l s y s t e m w i l l c o n s i s t o f e l e c t r i c a l w i r i n g r e p a ir
using standard electrical wiring repair procedures.
1-19. DIRECT/GENERAL SUPPORT TROUBLESHOOTING PROCEDURES.
a.
Direct/general support troubleshooting procedures cover the most common
malfunctions that may be repaired at the direct/general support level. Repair or
adjustment requiring specialized equipment is not authorized unless such equipment
i s a v a i l a b l e .
Troubleshooting procedures used by lower level maintenance should be
conducted in addition to the direct/general support troubleshooting procedures.
b. This manual cannot list all the possible malfunctions or every possible
t e s t / i n s p e c t i o n a n d c o r r e c t i v e a c t i o n .
I f a m a l f u n c t i o n i s n o t l i s t e d o r c o r r e c t ed
b y a l i s t e d c o r r e c t i v e a c t i o n , n o t i f y y o u r s u p e r v i s o r .
For unidentified malfunctions, use the facing schematic or the foldout
located at the end of this manual for further fault analysis .
1-87
c.