TM 5-6675-319-14
Table 1-2. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. BLACKOUT SWITCH DOES NOT OPERATE - Cont
Step 1.
Check blackout switch position.
(a) If switch is ON, proceed to step 2.
(b) If switch is OFF, reset switch to BLACKOUT.
Step 2.
Check to see that striker plate contacts roller on microswitch.
(a) Loosen screws and move plate up or down until microswitch
operates .
( b ) I f b l a c k o u t s w i t c h s t i l l f a i l s t o o p e r a t e , r e f e r to
organizational maintenance.
1-10.
MAINTENANCE PROCEDURES.
This section contains instructions covering operator maintenance functions
f o r t h e R e c t i f i e r I S e c t i o n.
Personnel required are listed only if the task requires
more than one.
b. After completing each maintenance procedure, perform operational check to be
sure that equipment is properly functioning .
INDEX
PROCEDURE
PARAGRAPH
Replace
Fluorescent
Lamp
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1-10.1
Service
Ventilation
Ducts
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1-10.2
Replace Blackout/Dome Light . . . . . . . . . . . . . . . . . . . . . . 1-10.3
1-50
a.