r. Add several drops of SAE 20 weight oil (Item 20, Appendix E) to two APL motor
lubrication fittings.
s.
Use cheesecloth to remove any oil or grease deposits from components.
t .
Check that insulation and wiring are not damaged or broken.
u.
Check that wiring is not stretched between terminals or around sharp edges.
v .
Reinstall APL left cover, and secure with four screws and washers.
WARNING
To prevent serious injury, two men are required to move equipment for
maintenance operations.
Equipment weighs approximately 500 lbs.
9-70
TM 5-6675-319-14