TM 5-6675-319-14
d.
e .
f .
g.
h.
i .
j .
k .
l .
m.
n.
o.
p.
NOTE
Do not disconnect wires to transducer.
Remove three screws, one nut, and one washer holding circuit board to
c h a s s i s.
Tag and disconnect power cord wire and circuit board wire from circuit
board.
Disconnect capacitor wires from circuit board.
Tag and disconnect two transducer wires from circuit board.
Remove defective circuit board.
I n s t a l l n e w c i r c u i t b o a r d .
Reconnect two transducer wires to circuit board.
Reconnect capacitor wires to circuit board.
Reconnect circuit board wire and power cord wire to circuit board.
Reinstall one washer, one nut, and three screws holding circuit board to
c h a s s i s.
Reinstall stainless steel tank and casing. Secure with screws and
washers.
F i l l s t a i n l e s s s t e e l t a n k 1 / 3 f u l l w i t h w a t e r.
Plug in power cord and turn power on. Check that water surface
a g i t a t e s .
8-17.
PREPARATION FOR STORAGE OR SHIPMENT.
Contact your battalion for packing
and shipping instructions.
Section V DIRECT/GENERAL SUPPORT MAINTENANCE
There are no direct/general support maintenance procedures assigned for this
equipment.
8-17/(8-18 blank)