TM 5-6675-319-14
Table 4-2. TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
LAMPS INOPERATIVE.
Step 1.
Check that power cord is plugged in.
(a) If power cord is plugged in, proceed to step 2.
(b) Plug in power cord.
Step 2.
Check for switch in proper position.
( a ) I f s w i t c h i s i n p r o p e r p o s i t i o n , p r o c e e d t o s t e p 3 .
( b ) P o s i t i o n s w i t c h .
Step 3.
Check for defective lamp.
(a) If lamp is not defective, proceed to step 4.
(b) Replace defective lamp (paragraph 4-10.1) .
Step 4.
Check for defective starter.
Replace starter (paragraph 4-10.2).
2. ONE OR MORE LAMPS FLICKER.
Step 1.
Check for defective lamp.
(a) If lamp is not defective, proceed to step 2.
(b) Replace lamp (paragraph 4 - 10 . 1).
Step 2.
Check for defective starter.
Replace starter (paragraph 4-10.2)
4-7