TM 5-6675-318-14
Table 7-8. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9. DISPLAY FLASHES EACH TIME LIBRARY PROGRAM IS CALLED - Cont
(e) Insert library module as shown, so that notch points toward
top of calculator, and labeled side is up.
(f)
Slide
cover
panel
back
in
place.
10. DISPLAY FLASHES OR PRODUCES INCORRECT RESULTS WHEN RUNNING A LIBRARY PROGRAM.
Step 1.
Check that correct library program was used.
(a) If program is correct, proceed to step 2.
(b) Call correct library program.
Step 2.
Check that correct call procedure was used.
(a) If call procedure is correct, proceed to step 3.
(b) Repeat program call.
Step 3.
Check to see if partitioning of data registers is sufficient for
program.
( a ) I f p a r t i t i o n i n g i s c o r r e c t , p r o c e e d t o s t e p 4 .
(b) Repartition calculator memory.
Step 4.
Check to see if calculator is operating in fixed-decimal format.
( a ) I f f o r m a t i s c o r r e c t , p r o c e e d t o s t e p 5 .
(b) Remove format by pressing
, and Fix, and rerun program.
Step 5.
Press
,
and = to run library module diagnostic.
I f r e s u l t i s f l a s h i n g , p e r f o r m s t e p 2 o f m a l f u n c t i o n 9.
Step 6.
Repeat library module diagnostic.
If malfunction persists, install new or different library module.
7-66