TM 5-6675-318-14
NOTE
Do not disconnect wires to transducer.
d. Remove three screws, one nut, and one washer holding circuit board to
c h a s s i s.
e .
Tag and disconnect power cord wire and circuit board wire from circuit
board.
f . D i s c o n n e c t c a p a c i t o r w i r e s f r o m c i r c u i t b o a r d .
g .
Tag and disconnect two transducer wires from circuit board.
h. Remove defective circuit board.
i .
I n s t a l l n e w c i r c u i t b o a r d.
j. Reconnect two transducer wires to circuit board .
k . R e c o n n e c t c a p a c i t o r w i r e s t o c i r c u i t b o a r d.
l .
Reconnect circuit board wire and power cord wire to circuit board.
m.
Reinstall one washer, one nut, and three screws holding circuit board to
c h a s s i s .
n .
Reinstall stainless steel tank and casing. Secure with screws and
washers.
o .
F i l l s t a i n l e s s s t e e l t a n k 1 / 3 f u l l w i t h w a t e r.
p.
Plug in power cord and turn power on. Check that water surface
a g i t a t e s.
6-17. PREPARATION FOR STORAGE OR SHIPMENT. Contact your battalion for packing
a n d s h i p p i n g i n s t r u c t i o n s .
Section V DIRECT/GENERAL SUPPORT MAINTENANCE
There are no direct/general support maintenance procedures assigned for this
equipment.
6-17/(6-18 blank)