TM 5-6675-318-14
Power Requirements
Current Draw
Average
Standby
T r a c k i n g ( D i s p l a y o f f)
Peak
Power Consumption at 25°C (77°F)
Average
Standby
Temperature Limitations, Receiver/Processor
Operating
Storage
Antenna
Humidity - Operating and Storage
A l t i t u d e
Operating
Storage/Transporting
External 5 MHz Reference
Tape Cassette Transport
Recording Technique
Read/Write Speed
Rewind Speed
I n t e r n a l , 1 2 V d c , 5 .0
amp hour battery with
c h a r g i n g c i r c u it
External, 10.5-16.0 V dc,
i n t e r n a l l y r e g u l a t e d
1.0 amp
0.41 amp
2.75 amps
4.0 amps
12 W
5 W
-25°C to 55°C
(-13° F to 131° F)
-55°C to 100°C
(-67°F to 212° F)
-60°C to 85°C
(-76° F to 188°F)
Up to 100% from 0°C to 55°C
(32°F to 131°F)
4600 m (Up to 15,000 ft)
15,240 m (Up to 50,000 ft)
Rubidium or Cesium stan-
dard with 1 V rms output
B i p h a s e L e v e l ( f u l ly
ANSI/ECMA/ISO compatible)
25.4 cm/s (10 in./s)
152.4 cm/s (60 in./s)
Change 3 4-7