TM 5-6675-317-14
Table 1-4. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
FLUORESCENT CEILING LAMP IS INOPERATIVE - Cont
Step 2.
Check for continuity of lamp ballast.
(a) If continuity exists, proceed to step 3.
(b) If continuity does not exist, replace lamp ballast (paragraph
1-16.1).
Step 3.
Check for shorts in RF filter.
Replace RF filter (paragraph 1-16.2).
2.
VENTILATION FAN IS INOPERATIVE.
Check on/off switch for continuity.
(a) If continuity exists, replace fan (paragraph 1-16.9).
(b) If continuity does not exist, replace switch (paragraph 1-
1 6 . 4 ).
3.
EMERGENCY LIGHTS ARE INOPERATIVE.
Press in test indicator.
If lamps do not light, replace emergency light assembly (paragraph
1-16.11).
4.
NO POWER TO EQUIPMENT.
Step 1.
Check circuit breaker ON/OFF
(a) If circuit breaker is
(b) If circuit breaker is
(c) If circuit breaker trips
supervisor.
position.
ON, proceed to step 2.
OFF, turn ON.
repeatedly, notify power supply
1-59