TM-5-6675-316-14
B - Before
D - During
A - After
ITEM
NO.
1
lN-
TER-
VAL
B
Table 3-2. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES
NOTE
If the equipment must be kept in continuous operation, check and service on-
ly those items that can be checked and serviced without disturbing operation.
Make the complete checks and services when the equipment can be shut
down.
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
M - Monthly
s
- Semiannually
Q - Quarterly
BI - Biennially
ITEM TO BE INSPECTED
PROCEDURE
COMBINED DRAFTING AND MEASURING MACHINE
Inspect Machine.
1.
2.
3.
4.
5.
6.
7.
8.
Inspect cabinets, casings, frames, and other
exterior surfaces of machine for signs of damage,
such as cracks and breaks.
Check that all cables are connected and
are tight.
Check glass surface and pinion racks for dirt
and foreign particles. Clean as required.
Check teletype platen for dirt and foreign
particles, Clean as required.
Check that keys on operators console keyboard
are free.
Turn on machine and controller. Check that
machine fluorescent lights and ventilation
fans are on. Check that controller power
button is lit and operators console displays
asterisk (*) in its right-hand corner. Check
that you can hear ventilation fans in rear of
cabinet working.
Turn on XY Display and press RESET on
digitizing keyboard. Check that display shows
all zeros and keyboard measuring mode display
shows an E.
Turn teletype power switch to LOCAL. Check that
it is on by listening for hum of drive motor
located beneath paper roll inside cabinet. .
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
Glass broken
or cracked.
Loose cables.
Keys stuck.
Ventilation
fans inoper-
ative.
XY display
inoperative.
Drive motor
not on.
Change 1