TM 5-6675-316-14
Drill pop rivets from hinged cover to remove vent cover.
a.
b. Remove defective cover and transfer mounting hardware to new cover.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially dan-
gerous to personnel and property. Avoid repeated and prolonged skin
contact. Wear solvent-impermeable gloves and eye/face protective
equipment when using solvent. Do not use near open flame or excessive
heat. Flash point of solvent is 100 F to 138 F (38 C to 59 C).
Scrape gasket off van body and clean area with solvent P-D-680.
c.
d.
Secure new gasket to van body with adhesive.
e.
Aline fan cover and pop rivet to hinge.
f.
Test cover for tightness of closure.
1-77