TM 5-6675-315-14
b.
Make certain that connections and cable receptacles on the outside of the section are free of frost, snow, and ice.
c.
When section heaters are not operating or when the section is being transported, liquid consumable supplies may
freeze, break their containers, then melt, and ruin equipment or documents. Store those items in an area to prevent
equipment or document damage.
1-7.3 Operation in Extreme Heat. The operation of the internal equipment is performed within environmentally controlled
conditions; however, during transportation or when air-conditioning units are not operating, consumable supplies may
suffer reduced shelf life, and internal components may have accelerated deterioration of gaskets, seals, or insulation.
1-7.4 Operation in Tropical Conditions. Fungi, mildew, or mold will form on and in equipment, documents, and supplies if
internal environmental control equipment is not operating and outside heat and humidity are allowed to enter the section.
1-7.5 Operation in Desert Conditions. Dust, grit, and sand will ruin supplies, equipment, and documents. Extreme care
must be taken to prevent dust, grit, and sand from entering into the section. Air filters will be changed whenever airflow
is restricted, and cleaning of section interior must be conducted more frequently than specified by PMCS schedules.
1-7.6 Emergency Procedures. There are no specific emergency procedures for operation of the section.
1-7.7 Emergency Means of Exit. In the event personnel are locked in the section, the tab may be turned to the left until
the bail on the padlock falls free. The door handle is now free to turn.
1-41