TM 5-6675-315-14
2-34. ORGANIZATIONAL TROUBLESHOOTING PROCEDURES.
a.
Organizational troubleshooting procedures cover the most common malfunctions that may be repaired at the
organizational level. Repair or adjustment requiring specialized equipment is not authorized unless such equipment is
available. Troubleshooting procedures used by the operator should be conducted in addition to the organizational
troubleshooting procedures.
b.
This manual cannot list all the possible malfunctions or every possible test/ inspection and corrective action. If a
malfunction is not listed or corrected by a listed corrective action, notify your supervisor.
c.
For unidentified malfunctions, use the facing schematic or the foldout located at the end of this manual for further
fault analysis.
Table 2-9. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
SHREDDER-BAGGER CONTROLS AND INDICATORS DO NOT RESPOND.
Step 1.
Check to see if circuit breaker is tripped.
(a) If circuit breaker is on, proceed to step 2.
(b) Reset circuit breaker.
Step 2.
Check for any loose wire connections.
(a) If all connections are tight, proceed to step 3.
(b) Tighten loose connections.
Step 3.
Check bale chamber full lamp by performing continuity test.
(a) If no continuity exists, replace lamp.
(b) Refer to direct/general support maintenance.
2-194