TM 5-6675-315-14
s.
Remove filter housing cover bolts and remove filter cover, clean filter, and then top off oil.
t.
Turn on circuit breaker.
u.
Turn on main power switch and cycle ram.
v.
Check connecting tube for leaks.
w.
Reinstall panels.
x.
Reinstall feed table.
2-16.10 Replace Relays.
MOS:
83FJ6, Reproduction Equipment Repairer
TOOLS:
Flat Tip Screwdriver
Wire-Stripping Pliers (AWG 10-22)
5 mm Hex Head Key Wrench
SUPPLIES:
Relay SS
Relay SV
Relay MP
Relay SR
Overload Relay eMP
Overload Relay eSV
Timer 2R
Timer X
Electrical Connectors
WARNING
Death or serious injury may occur from electrical shock unless power is turned off before
servicing.
a.
Turn off circuit breaker.
b.
Turn off main power switch.
c.
Lower front panel.
Change 1 2-102