TM 5-6675-314-14
1-16.5 Replace Blackout/Dome Light Microswitch.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: Flat Tip Screwdriver
6 in. Adjustable Wrench
SUPPLIES: Microswitch
Death or serious injury may occur from electrical shock unless power is
o f f b e f o r e s e r v i c i n g.
a.
b.
c .
d.
e.
f .
g.
h.
i .
Turn off blackout/dome light circuit breaker.
Remove conduit cover.
Remove nut and pull out switch to expose wiring.
Disconnect wires from defective switch.
Connect wires to new switch.
Install switch and secure with nut .
A d j u s t s t r i k e r p l a t e u n t i l p l a t e c o n t a c t s r o l l e r s .
Reinstall conduit cover.
Turn on circuit breaker.
1 - 6 5