TM 5-6675-313-14
(b). If statistical problem involves only one variable (x), clear storage
registers R.0 through R.5 and Y-register.
press
q
,~, and m .
Key number into X-register.
Press ~ .
NOTE
Unlike storage register arithmetic, the accumulation operation allows over-
flows (i.e., number whose magnitudes are greater than 9.99999999 x 10 99)
in storage registers R.0 through R.5 without indicating Error 1 in the display.
(c). To use any of the accumulations,
recall contents of desired storage register
into displayed X-register by pressing ~
q
followed by the number of the regis-
ter.
If this is done immediately after pressing D or ~- , the accumulation recal-
led is written over the number of data pair entries (n) in the display. To use both
~xand ~y
, press I@ El .
This simultaneously copies ~x from R.1 into
displayed X-register and copies
S
y from R.3 into Y-register. If this is done
immediately after pressing + ,x- , ~
or =
, the number in the Y-
register is first lifted into the Z-register.
Otherwise, the numbers in the X- and
Y-registers are f rst lifted into Z- and T- registers, respectively.
find xx, ~x2, ~y, ~y2, and~xy for the paired values of x and
Example: To
y listed below, press
y 7 5 9
x 5 3 8
Keystrokes
Display
q
CLEAR z
0 l 0000
7.0000
1.0000
5.0000
200000
9.0000
3.0000
Clear statistical storage
registers.
(Display shown
assumes no results remain
from previous calcul ations.)
First pair is accumulated: n=1
Second pair is accumulated:
n=2
Third pair is accumulated: n=3
6-28