2-11. CAGING KNOB (Continued).
L O C A T I O N / l T E M
A C T I ON
R E M A R K S
2 . C a g i n g K n ob
a.
Install two setscrews (1)
partially into caging knob (2).
b .
Place caging knob (2) onto
caging shaft (3).
A p p ly
MIL-S-22473,
Grade N, Form R
primer, item 5,
Appendix C to the
t w o s e t s c r e w s a nd
allow to air dry for 5
seconds. Apply lock-
i n g s e a l a n t ,
MIL-S-46163,
Grade
N,
Type II, item 2, Ap-
pendix C, to the first
few threads of two
set screws.
N O T E
Allow sufficient space between caging knob and GRU housing to prevent
binding.
c.
Tighten two setscrews.