Table 8-6.1. PADS Test Set Self-Test Procedure Using Tape Reader, Part No. 877406-2 - Continued
Malfunction
Test procedure
Normal indication
indication/corrective action
ac.
ad.
ae.
af.
ag.
b. Adjust the rangefinder mechanism
located on the left side of the
TTY by typing RY and observing
the printout, Adjust the range-
finder clockwise until the TTY
prints other than RY. Note the
position of the rangefinder dial.
Now turn rangefinder counter-
clockwise and observe correct RY
printout and continue in a coun-
terclockwise direction until other
than RY is printed out. Note this
position of the rangefinder dial.
Set the rangefinder in the middle
of the two extremes
c. If TTY still does not print out
correctly, replace or repair TTY
Turn TTY keyboard MOTOR
switch to OFF
Press SELF TEST switch-indica-
tor to off
Press SELF TEST switch-indica-
tor to on
Press MEMORY LOAD, RE-
VERSE, VERIFY and EXE-
CUTE switch-indicators in order
given
Press and release PADS ON/
OFF and ENTER switch-indica-
tors simultaneously
SELF TEST switch-indicator goes
off. EXECUTE switch-indicator
lights. FAILURE/ACTION indi-
cator displays 77
SELF TEST switch-indicator lights.
IMU FAIL/COMP FAIL indica-
tor remains on. Self-test tape may
or may not move forward. ON
portion
of PADS ON/OFF
switch-indicator lights. EXECUTE
switch-indicator goes off
Each switch-indicator, except EXE-
CUTE, lights
OFF portion of PADS ON/OFF
switch-indicator lights and ON
portion goes off. Self-test tape
runs forward and then stops.
FAILURE/ACTION
indicator
displays 00 when tape stops
SELF TEST switch-indicator does
not go off:
a. Check SELF TEST switch-indica-
tor for proper operation or
shorted wiring
b. Replace A3
EXECUTE switch-indicator does not
light: Replace buffer unit, then
Al, and then A3
SELF TEST or PADS ON switch-
indicator does not light: Recheck
step i because the self-test cannot
proceed unless the sequence of
step i was completed correctly
A switch-indicator does not light
when pressed: Check the specific
switch-indicator for continuity
Self-test tape does not run forward:
a. Check each switch-indicator or
switch for proper operation, re-
place if defective
b. Replace A3
c. Replace A1
d. Replace A2
Change 1
8-54.11