TM 5-3610-285-14
Table 1-4. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
Electrical shock hazard. Be sure power is off when checking continuity at troubleshooting
points. Death or serious injury could result from failure to do so.
1. FLUORESCENT CEILING LAMP IS INOPERATIVE.
Step 1. Check for continuity of fluorescent lamp switch.
(a) If continuity exists, proceed to step 2.
(b) If continuity does not exist, replace switch (paragraph 1-16.3).
Step 2. Check for continuity of lamp ballast.
(a) If continuity exists, proceed to step 3.
(b) If continuity does not exist, replace lamp ballast (paragraph 1-16.1).
Step 3. Check for shorts in RF filter.
Replace RF filter (paragraph 1-16.2).
2. EXHAUST FAN IS INOPERATIVE.
Check ON/OFF switch for continuity.
(a) If continuity exists, replace fan (paragraph 1-16.9).
(b) If continuity does not exist, replace switch (paragraph 1-16.4).
1-56