Table 5-5. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
DRYER HEATER DOES NOT WARM DRYING AIR. ROLLERS ROTATE - Cont
WARNING
Electrical shock hazard. You must stand on rubber matting while performing this
procedure.
Step 1. Check voltage between terminal block connector 3-24 and ground.
(a)
If 120 V ac is present, proceed to step 2.
(b)
If voltage is not present, proceed to step 6.
5-111